CH-81-09-1 -- Determination of Annual Efficiency of Vented Heaters Equipped with Thermally Activated Vent Dampers

CH-81-09-1 -- Determination of Annual Efficiency of Vented Heaters Equipped with Thermally Activated Vent Dampers

E.R. Kweller, P.E.; W.F. Mullis ASHRAE / 1981 / 16 pages

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$6.45 tax incl.

$15.00 tax incl.

(price reduced by 57 %)

1000 items in stock

Part-load space heater efficiency requires the determination of five flue losses. These are latent heat loss (LL), on-period sensible heat loss (LS,ON), on-period infiltration loss (LI,ON), off-period sensible heat loss (LS,OFF) and off-period infiltration loss (LI,OFF).

We determined:
-- Which of the part-load losses can be adequately measured using the current DOE procedure?
-- Which part load losses cannot be measured using the DOE procedure?
-- Seasonal efficiencies for three vented heaters using the current and a modified procedure.

All stack losses associated with the calculation of part-load utilization efficiency (nu) were reviewed in the development of a test method for heaters equipped with the thermally-activated vent damper. Annual fuel utilization efficiency and associated energy savings were determined for two thermal vent dampers tested with three types of gas-fueled heaters which operate in either the cycling mode or in the modulating fuel input mode.

Test results showed energy savings from 1 to 9% depending on the type of heater as well as the type of damper used.

Citation: ASHRAE Transactions, Volume 87, Part 1, Chicago, Illinois